Stowarzyszenie Partnerstwo dla Krajny i Pałuk Program Rozwoju Obszarów Wiejskich +48 52 382 44 50

Thermostatic mixing valves MIX THERM for heating

Description:


Thermostatic mixing valves  MIX THERM series are designed to regulate the power factor of the installation of central heating radiators and floor. MIX THERM-R valve is equipped with a brass female nut 1 ½ " and 1" EPDM gasket.

 




 


                                                       

Applications:

When installing, please observe the following connections:
HOT (H) = hot-water supply
COLD (C) = cold water supply
MIX = mixed water exit

It is recommended to install a filter and check valve.

Markings on the handle correspond to the proper temperature water mixed (see table).

Valve adjustment 20 ° - 45 °C

Position of handle: MIN  1
2
3
4
5
MAX
Temp.  [°C]: -
20
26
32
38
45
-


Valve adjustment 35° - 60°C

Position of handle:MIN  1
2
3
4
5
MAX
Temp.  [°C]: -
35
42
49
55
60
-




Technical data:

Diameter :
1"
Max operating pressure:
10 bar
Min pressure:
0,2 bar
Recommended operating pressure:
1 - 5 bar
Recommendation: for higher pressures it is recommended to mount the pressure reducer
Max. temp. of hot water
85°C
Adjustable temperature range:
35° - 60°C (+/- 2K)
or
20° - 45°C (+/- 2K)
Temperature scale:
1 - 5
Setting tolerance:
+/- 2°C
Kv
3,4


Type
    Size    
    Catalog number 
Thermostatic mixing valves MIX THERM 20-45°C                                                                          
1" 601206
Thermostatic mixing valves MIX THERM 35-60°C     
1"
601205
Thermostatic mixing valves MIX THERM - R 20-45°C     
1"
601203
Thermostatic mixing valves MIX THERM - R 35-60°C     
1"
601202




Mounting and operating instructions

Photos of high quality

  Instruction thermostatic mixing valve MIX THERM
  Thermostatic mixing valve MIX THERM
  Catalog page thermostatic mixing valve MIX THERM
  Thermostatic mixing valve MIX THERM - R
  Catalog page thermostatic mixing valve MIX THERM - R